{"product_id":"superpro-therm-b1-temperature-analog-controller","title":"SuperPro THERM-B1 analogue temperature controller","description":"\u003cp\u003eSuperPro \u003cstrong\u003eTHERM-B1\u003c\/strong\u003e is a temperature controller that can manage a cooling or heating device.\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eInput voltage \/ max. current: \u003cstrong\u003e230V\u003c\/strong\u003e \/ \u003cstrong\u003e10Amps\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli\u003eMax. output current: \u003cstrong\u003e10Amps \u003c\/strong\u003eat\u003cstrong\u003e \u003c\/strong\u003e\u003cstrong\u003e230V AC\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli\u003eControlled temperature range: from \u003cstrong\u003e7°C\u003c\/strong\u003e to \u003cstrong\u003e35°C\u003c\/strong\u003e \u003c\/li\u003e\r\n\t\u003cli\u003eDay or night mode settings: \u003cstrong\u003evia photocell\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli\u003eTemperature accuracy: \u003cstrong\u003e+\/- 3°C\u003c\/strong\u003e \u003c\/li\u003e\r\n\t\u003cli\u003eActivation interval (hysteresis): \u003cstrong\u003e2°C\u003c\/strong\u003e\n\u003c\/li\u003e\r\n\t\u003cli\u003eWeight \/ dimensions: \u003cstrong\u003e\u0026lt; 0.5 kg\u003c\/strong\u003e \/ \u003cstrong\u003e78*90*150 mm \u003c\/strong\u003e\n\u003c\/li\u003e\r\n\u003c\/ul\u003e\n\u003cp\u003eThe controller can operate in different modes during light and dark periods, switching automatically via the built-in photocell. It is easily adjusted with rotary knobs. Three indicator lights show the controller's current status.\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cspan style=\"color:#FF0000;\"\u003e\u003cstrong\u003eWARNING\u003c\/strong\u003e: The controller is not waterproof. Install only in locations where there is no risk of getting wet!!!\u003c\/span\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e:\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003ePlug \u003cstrong\u003eTHERM-B1\u003c\/strong\u003e into a standard \u003cstrong\u003e220V\u003c\/strong\u003e socket. For permanent mounting, use the tab at the top of the housing.\u003c\/li\u003e\r\n\t\u003cli\u003eConnect the device or devices whose operation will be controlled. Do not exceed the maximum current (\u003cstrong\u003e10 A\u003c\/strong\u003e, approximately \u003cstrong\u003e2200W\u003c\/strong\u003e). To control devices with greater power, use a relay.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eOperating modes\u003c\/strong\u003e:\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eBefore using the controller, set the operating mode — \u003cstrong\u003e\"COOLING\"\u003c\/strong\u003e or \u003cstrong\u003e\"HEATING\"\u003c\/strong\u003e. Select the mode using the two rotary knobs. The controller must be connected to the mains.\u003c\/li\u003e\r\n\t\u003cli\u003eTo select \u003cstrong\u003e\"COOLING\"\u003c\/strong\u003e mode: turn both knobs fully to the left. After a few seconds, the indicator lights start flashing, after which only the \u003cstrong\u003e\"COOL\"\u003c\/strong\u003e indicator remains lit.\u003c\/li\u003e\r\n\t\u003cli\u003eTo select \u003cstrong\u003e \"HEATING\"\u003c\/strong\u003e mode: turn both knobs fully to the right. After a few seconds, the indicator lights start flashing, after which only the \u003cstrong\u003e\"HEAT\"\u003c\/strong\u003e indicator remains lit.\u003c\/li\u003e\r\n\t\u003cli\u003eOnce you have selected an operating mode, turn the knobs to the desired temperature values.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eSetting up the controller\u003c\/strong\u003e:\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eSet the knobs to the desired temperature values for the light (\u003cstrong\u003eDAY\u003c\/strong\u003e) and dark (\u003cstrong\u003eNIGHT\u003c\/strong\u003e) periods*. The photocell switches between them automatically. When temperature exceeds the set value, the controller supplies power to the connected device. Since the controller has an activation range (hysteresis) of \u003cstrong\u003e2°C\u003c\/strong\u003e, it continues supplying power until temperature drops by \u003cstrong\u003e2°C\u003c\/strong\u003e. When power is supplied, the \u003cstrong\u003e\"OUTPUT ON\"\u003c\/strong\u003e indicator is lit.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cem\u003e*The example is for \u003cstrong\u003e\"COOLING\"\u003c\/strong\u003e mode. In this mode, the setting is the maximum permitted temperature. For \u003cstrong\u003e\"HEATING\"\u003c\/strong\u003e mode, it is the minimum.\u003c\/em\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eQuestions and Answers:\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eHow do I know whether the photocell is working?\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eThe photocell operates with a 30-second delay to prevent activation from accidental light or darkness. The green \u003cstrong\u003e\"DAYTIME\"\u003c\/strong\u003e indicator on the right side of the housing lights up when the photocell is in day mode.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eCan I connect more than one device to the timer?\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eYes, provided the maximum current is not exceeded (\u003cstrong\u003e10 A\u003c\/strong\u003e, or approximately \u003cstrong\u003e2200W\u003c\/strong\u003e). For continuous use, the load is recommended to be up to \u003cstrong\u003e75%\u003c\/strong\u003e of the maximum permitted value.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eDoes the room temperature not match the setting?\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eThe humidity sensor is located at the bottom of the housing, enclosed by a plastic \"cage\". Check that the controller is not affected by other appliances or direct light, and that it has access to the same air.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eIs the controller not supplying power?\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eCheck whether power is supplied to the controller. If the controller does not work, contact your distributor.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eAre the red and yellow lights flashing?\u003c\/strong\u003e\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eThe controller has been overloaded. Disconnect it from the mains and reconnect it after 5 sec. Check that the power of the device connected to the controller does not exceed the permitted limit (current up to 10A).\u003c\/li\u003e\r\n\u003c\/ul\u003e","brand":"No Brand","offers":[{"title":"Default Title","offer_id":55115828789590,"sku":"12321","price":69.02,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/product_4560.jpg?v=1787849846","url":"https:\/\/urbanbotaniks.com\/en-eu\/products\/superpro-therm-b1-temperature-analog-controller","provider":"UrbanBotaniks Grow Shop","version":"1.0","type":"link"}