{"title":"G-Systems controllers for ventilation and climate","description":"\u003cp\u003eG-Systems controllers for regulating compatible fans and controlling operation according to climate settings.\u003c\/p\u003e\u003ch2\u003eHow to choose\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eDistinguish between electronic speed control, a step transformer, and an EC signal output.\u003c\/li\u003e\n\u003cli\u003eFor two fans, check the limits of each output and the overall configuration.\u003c\/li\u003e\n\u003cli\u003eBalancing the incoming and outgoing airflow helps maintain the desired direction of air exchange.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eRelated categories\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eVentilation and climate controllers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/en\/collections\/timers-and-controllers-lighting\"\u003eLighting controllers and timer boards\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"gse-temperature-min-speed-and-negative-pressure-controller-2-fans","title":"GSE, dual-fan and negative-pressure controller","description":"\u003cp\u003eA controller with temperature, minimum speed, and negative pressure settings for controlling intake and exhaust fans.\u003c\/p\u003e\n\u003cp\u003eDimensions and technical data:\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eProduct dimensions:\u003cstrong\u003e W80xH80xD130mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003ePackage dimensions: \u003cstrong\u003eW150xH110xD170mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eDesigned for: \u003cstrong\u003e2A \/ 2x200W \/ TRIAC 2x16A\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eVoltage: \u003cstrong\u003e230V \/ 50HZ\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eThe 5V digital sensor measures temperatures from \u003cstrong\u003e–55°C to +125°C\u003c\/strong\u003e (\u003cstrong\u003e–67°F to +257°F \u003c\/strong\u003e)\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e0.5°C \u003c\/strong\u003eAccuracy from \u003cstrong\u003e–10°C \u003c\/strong\u003eto \u003cstrong\u003e+85°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eProtection rating: \u003cstrong\u003eIP54\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSetting range:\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eTemperature: from \u003cstrong\u003e20C° to 30C°\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eMinimum speed: \u003cstrong\u003eoff, 20%, 100%\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eNegative pressure: \u003cstrong\u003e100%\u003c\/strong\u003e to \u003cstrong\u003e50%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstructions for use \u003cu\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/ubm-3b704b4fa6e8614436da.pdf?v=1787840796\"\u003e\u003cstrong\u003ehere!\u003c\/strong\u003e\u003c\/a\u003e\u003c\/u\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eThe controller operates one or two fans: one for intake and one for exhaust, or two for exhaust. Connect the exhaust fan to \u003cstrong\u003e\"Fan 1\"\u003c\/strong\u003e and the intake fan to \u003cstrong\u003e\"Fan 2\"\u003c\/strong\u003e. Set the desired temperature.\u003c\/li\u003e\n\t\u003cli\u003eThe \u003cstrong\u003e\"Minimum Speed\"\u003c\/strong\u003e setting sets the exhaust fan's minimum speed as a percentage of its maximum speed. Set it to \u003cstrong\u003e\"Off\"\u003c\/strong\u003e to stop ventilation when it isn't needed; any other setting will keep it running at the selected speed.\u003c\/li\u003e\n\t\u003cli\u003eThe \u003cstrong\u003e\"Negative Pressure\"\u003c\/strong\u003e setting sets the intake fan speed as a percentage of the exhaust fan speed. If you use this controller for \u003cstrong\u003e2\u003c\/strong\u003e exhaust fans, set it to \u003cstrong\u003e100%\u003c\/strong\u003e; otherwise, determine a suitable value by experimentation.\u003c\/li\u003e\n\t\u003cli\u003eAs the temperature rises, the fan speeds gradually increase, reaching \u003cstrong\u003e100%\u003c\/strong\u003e when the temperature rises by \u003cstrong\u003e2°\u003c\/strong\u003e. As the temperature drops, the speeds decrease again to the level set under \u003cstrong\u003e\"Minimum Speed\"\u003c\/strong\u003e.\u003c\/li\u003e\n\t\u003cli\u003eMaintains a constant temperature, while negative pressure contains odors.\u003c\/li\u003e\n\t\u003cli\u003eCan be used for two exhaust fans, provided there is free airflow into the room.\u003c\/li\u003e\n\t\u003cli\u003eReady to use, reliable, with a waterproof housing, socket covers, and a low-voltage sensor, making it ideal for humid environments.\u003c\/li\u003e\n\t\u003cli\u003eThe sensor has a \u003cstrong\u003e4m\u003c\/strong\u003e cable that can be extended up to 50m.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eNegative pressure is adjusted by balancing the intake and exhaust fans. The TRIAC 2 × 16 A rating describes the components and does not mean a permitted load of 16 A on each fan output.\u003c\/p\u003e\u003ch2\u003eChoosing a climate controller\u003c\/h2\u003e\u003cp\u003eMatch the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different control. Follow the limits for the specific model.\u003c\/p\u003e\u003cp\u003eBrowse \u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eventilation and climate controllers\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115752571222,"sku":"12392","price":80.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/GSE-Temp-Min-Speed-and-Neg-Pressure-Controller-2-fans.webp?v=1787849780"},{"product_id":"spare-clock-tg-01-for-g-system-timers","title":"G-Systems TG-01, replacement timer for timed distribution board","description":"\u003cdiv\u003eReplacement Clock TG-01 for G-system timers.\u003c\/div\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cul\u003e\n\t\u003cli\u003evoltage: \u003cstrong\u003e230V \/ 50Hz\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eswitching interval: \u003cstrong\u003e15 min\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003epower reserve: \u003cstrong\u003eno\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emanual switching: \u003cstrong\u003eOn\u003c\/strong\u003e - \u003cstrong\u003eAutomatic\u003c\/strong\u003e - \u003cstrong\u003eOff\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eImax: \u003cstrong\u003e16 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eUmax: \u003cstrong\u003e230 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eVAmax:\u003cstrong\u003e 3600 W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eBefore replacement\u003c\/h2\u003e\u003cp\u003eCheck the model, mounting dimensions, electrical ratings, and wiring diagram. Replace only with a compatible board, with the power disconnected.\u003c\/p\u003e\u003cp\u003eBrowse \u003ca href=\"\/en\/collections\/timers-and-controllers-lighting\"\u003elighting timers and boards\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115767316822,"sku":"878858","price":20.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/gsetimer.jpg?v=1794299369"},{"product_id":"gse-step-transformer-controller-for-temperature-1-fan-2-5a","title":"GSE, transformer temperature controller 2,5 A","description":"\u003cp\u003eA step-down transformer that lets you control fans without low-frequency noise at low speeds.\u003cbr\u003e\n\u003cbr\u003e\nThe six control steps help you better regulate the exhaust fan according to the temperature setting you have chosen.\u003cbr\u003e\n\u003cbr\u003e\nTwo buttons let you set the temperature and temperature hysteresis.\u003cbr\u003e\nUsing the built-in jumper - J1 (in the box), you can choose whether the fan continues running at minimum speed or stops when the desired temperature is reached. When J1 is closed, ventilation continues at minimum speed. When it is open, the fan stops completely.\u003cbr\u003e\n\u003cbr\u003e\nIt comes with a 4 m cable with a temperature and humidity sensor, an exhaust fan socket, and a waterproof enclosure.\u003cbr\u003e\n\u003cbr\u003e\n- temperature range: 20C° - 30C°\u003cbr\u003e\n- temperature hysteresis: 2C°-8C°\u003cbr\u003e\n- dimensions: 265mm х 300mm х 205mm\u003cbr\u003e\n- maximum current: 2,5 A\u003cbr\u003e\n- Voltage: 230V \/ 50HZ\u003cbr\u003e\n- Digital sensor 5V measures temperatures from –55°C to +125°C (–67°F to +257°F)\u003cbr\u003e\n- Accuracy: 0,5C° in the range from -10C° to +85C°; ±4,5%rh\u003cbr\u003e\n- Protection rating: IP54\u003c\/p\u003e\u003ch2\u003eChoosing a climate controller\u003c\/h2\u003e\u003cp\u003eConsider the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different control systems. Follow the specifications of the specific model.\u003c\/p\u003e\u003cp\u003eBrowse \u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eventilation and climate controllers\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115791696214,"sku":"12354","price":110.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/GSE-STEP-TRANSFORMER-controller-TEMP-1FAN-2-5A.webp?v=1787849815"},{"product_id":"gse-temperature-and-minimum-speed-controller-1-fan-10a","title":"GSE, temperature and minimum speed controller 10 A","description":"\u003cp\u003e\u003cstrong\u003eGSE Temperature and Minimum Speed Controller 10A\u003c\/strong\u003e is a speed controller for one or more exhaust fans used in indoor grow rooms.\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003emaintains a constant room temperature\u003c\/li\u003e\n\t\u003cli\u003eprovides a continuous minimum speed to maintain baseline air exchange\u003c\/li\u003e\n\t\u003cli\u003emax. current: \u003cstrong\u003e10.0A\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emax. load: \u003cstrong\u003e2300W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSetting range:\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003etemperature: \u003cstrong\u003e20C°\u003c\/strong\u003e to \u003cstrong\u003e30C°\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emin. speed: \u003cstrong\u003eoff\u003c\/strong\u003e, \u003cstrong\u003e20%\u003c\/strong\u003e to \u003cstrong\u003e100%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003edimensions W x H x D: \u003cstrong\u003e130x92x105mm.\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emax. current: \u003cstrong\u003e10.0A\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emax. load: \u003cstrong\u003e2300W\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003etemperature sensor with \u003cstrong\u003e4m.\u003c\/strong\u003e cable\u003c\/li\u003e\n\t\u003cli\u003evoltage: 230V, 50Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\t\u003cli\u003eUse the temperature setting knob to set the desired temperature, for example 24°C.\u003c\/li\u003e\n\t\u003cli\u003eUse the second knob to set the minimum speed, which should never drop during regulation; for example, we set this to 20%.\u003c\/li\u003e\n\t\u003cli\u003eThe minimum speed setting is the strongest setting and always overrides the temperature setting. If you set the minimum speed setting to OFF, the fan will stop running when the measured temperature is below the set temperature. The minimum speed setting has a 20% startup boost to provide enough power for the fan to run at low speed.\u003c\/li\u003e\n\t\u003cli\u003eThe hysteresis is a fixed value of 2°C. Hysteresis is the controlled range of fan speed. Within these 2°C, the fan speed changes from the lowest point, set by the minimum speed setting, to the highest control point, 100% fan speed, depending on the temperature.\u003c\/li\u003e\n\t\u003cli\u003eAs long as the temperature measured by the sensor is below your setting (24°C), the minimum speed regulator keeps the fan running at the minimum speed setting (20%). When the temperature rises above 24°C, the temperature LED turns on and the fan speed starts increasing based on the temperature over the next 2°C, up to 100% at 26°C.\u003c\/li\u003e\n\t\u003cli\u003eSmall fans can be adjusted from 0-100%, but with higher power consumption (large fans), the controller operates in semi-variable mode and automatically switches to 100% without variable control. The controller remains on until the temperature drops.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/em\u003e Setting a high minimum speed with large fans will cause it to run at 100% due to the internal overheating protection! Reduce the minimum speed!\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eChoosing a climate controller\u003c\/h2\u003e\u003cp\u003eMatch the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different control methods. Follow the limits specified for the specific model.\u003c\/p\u003e\u003cp\u003eBrowse \u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eventilation and climate controllers\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115795235158,"sku":"610440","price":113.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/D0_9A_D0_BE_D0_BD_D1_82_D1_80_D0_BE_D0_BB_D0_B5_D1_80-_D0_B7_D0_B0-_D1_82_D0_B5_D0_BC_D0_BF_D0_B5_D1_80_D0_B0_D1_82_D1_83_D1_80_D0_B0-_D0_B8-_D0_BC_D0_B8_D0_BD_D0_B8_D0_BC_D0_B0_D0_B_0155c840-9ca8-4b56-9fd0-5744d3e76c79.webp?v=1787849818"},{"product_id":"gse-hysteresis-controller-10a","title":"GSE 10 A, temperature, speed, and hysteresis controller","description":"\u003cp\u003eThe controller maintains the set temperature and prevents operation below the specified minimum speed or above the permitted maximum speed.\u003c\/p\u003e\nHysteresis determines the temperature range. \nIt can be easily controlled by adjusting your desired minimum speed, maximum speed, and hysteresis with four knobs.\nController: W x H x D = 160x100x90mm\nDesigned for: 10A 2300W\nVoltage: 230V \/ 50HZ\n5V digital sensor. Measures temperatures from -55°C to +125°C (-67°F to +257°F)\nAccuracy: 0.5°C from -10°C to +85°C\nProtection class: IP54\u003ch2\u003eChoosing a climate controller\u003c\/h2\u003e\u003cp\u003eConsider the load type and control method. An AC fan with adjustable voltage and an EC fan with a control input require different controls. Follow the limitations of the specific model.\u003c\/p\u003e\u003cp\u003eBrowse \u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eventilation and climate controllers\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115823251798,"sku":"610442","price":75.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/GSE-Hysteresis-controller-10A.webp?v=1792756056"},{"product_id":"gse-temperature-and-minimum-speed-controller-1-fan-5a","title":"GSE, temperature and minimum speed controller 5 A","description":"\u003cp\u003e\u003cstrong\u003eGSE temperature and minimum speed controller with 5A outlet\u003c\/strong\u003e is a speed controller for one or more exhaust fans used in indoor growing rooms.\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003emaintains a constant room temperature\u003c\/li\u003e\n\t\u003cli\u003eprovides a continuous minimum speed to maintain basic air exchange\u003c\/li\u003e\n\t\u003cli\u003emax. current: \u003cstrong\u003e5.0A\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emax. load: \u003cstrong\u003e1150W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSettings range:\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003etemperature: \u003cstrong\u003e20C°\u003c\/strong\u003e to \u003cstrong\u003e30C°\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emin. speed: \u003cstrong\u003eoff\u003c\/strong\u003e, \u003cstrong\u003e20%\u003c\/strong\u003e to \u003cstrong\u003e100%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003edimensions W x H x D: \u003cstrong\u003e75x110x90mm.\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emax. current: \u003cstrong\u003e5.0A\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003emax. load: \u003cstrong\u003e1150W\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003etemperature sensor with \u003cstrong\u003e2 m\u003c\/strong\u003e cable\u003c\/li\u003e\n\t\u003cli\u003evoltage: 230V, 50Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003ePlug the air fan into the outlet (5). Connect the temperature sensor (7), which has a 2 m cable, to the controller and choose a location for the sensor where you want to take the measurement.\u003c\/li\u003e\n\t\u003cli\u003eMake sure it is not directly exposed to a heat source or light, to ensure the most accurate measurement of the ambient air. Now plug the controller's plug (6) into an external outlet. The controller initializes, which can take up to 10 seconds; the green power LED (3) flashes, and the fans run at 50% power. After initialization, the green power LED (3) stays on continuously - the controller regulates from this point on.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstructions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col\u003e\n\t\u003cli\u003eUse the temperature setting button (1) to set the desired temperature, for example, 24°C.\u003c\/li\u003e\n\t\u003cli\u003eUse the second knob to set the minimum speed (2), which should never drop during regulation; for example, we set it to 20%.\u003c\/li\u003e\n\t\u003cli\u003eThe minimum speed setting is the most powerful setting and always overrides the temperature setting. If you set the minimum speed setting (2) to OFF, the fan will stop running when the measured temperature is below the set temperature. The minimum speed setting (2) has a 20% startup peak to provide enough power for the fan to run at low speed.\u003c\/li\u003e\n\t\u003cli\u003eThe hysteresis is a fixed value of 2°C. Hysteresis is the controlled range of the fan speed. Within these 2°C, the fan speed will change from the lowest point, set by the minimum speed setting (2), to the highest control point, 100% fan speed, depending on the temperature.\u003c\/li\u003e\n\t\u003cli\u003eWhile the temperature measured by sensor (7) is below your setting (24°C), the minimum speed regulator keeps the fan running at the minimum speed setting (20%). As the temperature rises above 24°C, the temperature LED (4) turns on and the fan speed starts to increase based on the temperature over the next 2°C, up to 100% when it reaches 26°C.\u003c\/li\u003e\n\t\u003cli\u003eSmall fans can be adjusted from 0-100%, but with higher power consumption (large fans), the controller operates in semi-variable mode and will automatically switch to 100%, without variable control. The controller stays on until the temperature drops.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cem\u003e\u003cstrong\u003eWarning!\u003c\/strong\u003e\u003c\/em\u003e Setting a high minimum speed with large fans will cause them to run at 100% due to internal overheating protection! Lower the minimum speed!\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eChoosing a climate controller\u003c\/h2\u003e\u003cp\u003eMatch the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations of the specific model.\u003c\/p\u003e\u003cp\u003eBrowse \u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eventilation and climate controllers\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115824038230,"sku":"610441","price":86.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/GSE-_D0_BA_D0_BE_D0_BD_D1_82_D1_80_D0_BE_D0_BB_D0_B5_D1_80-_D0_B7_D0_B0-_D1_82_D0_B5_D0_BC_D0_BF_D0_B5_D1_80_D0_B0_D1_82_D1_83_D1_80_D0_B0-_D0_B8-_D0_BC_D0_B8_D0_BD-_D1_81_D0_BA_D0_BE_40acdf43-a0e1-4810-a65e-06c6263e88c6.webp?v=1792756051"},{"product_id":"gse-digital-humidity-and-temperature-controller-2-fans-16a","title":"GSE - digital humidity and temperature controller (2 fans 16A)","description":"\u003cp\u003eDigital ventilation controller\u003cbr\u003e\n\u003cbr\u003e\n• 2 phase-controlled fan outputs – intake and exhaust\u003cbr\u003e\n• 2 additional programmable outputs, configurable as timers or linked to sensor readings\u003cbr\u003e\n• LCD screen\u003cbr\u003e\n• 1 combined air sensor for temperature, humidity and light\u003cbr\u003e\n• 1 waterproof temperature sensor\u003cbr\u003e\n• Robust aluminium enclosure\u003cbr\u003e\n• Up to 2200W load per output or 3600W total\u003cbr\u003e\n• Numerous options for day\/night settings\u003cbr\u003e\n• Depending on version: USB port for saving data to a flash drive (CSV format)\u003cbr\u003e\n• Free slot for a negative-pressure sensor\u003cbr\u003e\n• 2 m power cable\u003cbr\u003e\n• 4 m sensor cables, extendable to 10 m\u003cbr\u003e\n• Digital display and 4 buttons\u003cbr\u003e\n• Indicator lights for output activation\u003cbr\u003e\n\u003cbr\u003e\n\u003cbr\u003e\nTechnical data:\u003cbr\u003e\ndimensions: 150 x 210 x 110 mm\u003cbr\u003e\npower supply: 230V \/ 50Hz\u003cbr\u003e\nmax. power: 16A \/ 3600W\u003cbr\u003e\ntemperature and humidity sensor: 5V; -55°C ... +125°C; accuracy 0.5°C \/ ±4.5% RH\u003cbr\u003e\nwaterproof sensor: 5V, -55°C ... +125°C; accuracy 0.5°C\u003cbr\u003e\nprotection rating: IP54\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115831411030,"sku":"12391","price":250.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/product_6243.jpg?v=1792755739"},{"product_id":"gse-step-transformer-controller-for-humidity-and-temperature-1-fan-2-5a","title":"GSE, transformer temperature and humidity controller 2.5 A","description":"\u003cp\u003eStep-down transformer that lets you control fans without the low-frequency noise at low speed.\u003cbr\u003e\n\u003cbr\u003e\nThe six control settings help you better control the exhaust fan according to the temperature and humidity settings you have selected.\u003cbr\u003e\n\u003cbr\u003e\nThe four buttons let you set the temperature, temperature hysteresis, humidity and humidity hysteresis.\u003cbr\u003e\nUsing the built-in jumper - J1 (in the box), you can choose whether the fan continues running at minimum speed or stops when the desired temperature and humidity are reached. When J1 is closed, ventilation continues at minimum speed. When it is open, the fan stops completely.\u003cbr\u003e\n\u003cbr\u003e\nIt comes with a 4m cable with a temperature and humidity sensor, an exhaust fan outlet and a waterproof enclosure.\u003cbr\u003e\n\u003cbr\u003e\n- temperature range: 20C° - 30C°\u003cbr\u003e\n- temperature hysteresis: 2C°-8C°\u003cbr\u003e\n- humidity range: 30% - 100%\u003cbr\u003e\n- humidity hysteresis: 6%-30%\u003cbr\u003e\n- dimensions: 265mm х 300mm х 205mm\u003cbr\u003e\n- maximum current: 2,5 A\u003cbr\u003e\n- Voltage: 230V \/ 50HZ\u003cbr\u003e\n- Digital sensor 5V measures temperatures from –55°C to +125°C (–67°F to +257°F)\u003cbr\u003e\n- Accuracy: 0,5C° in the range from -10C° to +85C°; ±4,5%rh\u003cbr\u003e\n- Protection rating: IP54\u003cbr\u003e\n \u003c\/p\u003e\u003ch2\u003eChoosing a climate controller\u003c\/h2\u003e\u003cp\u003eConsider the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations of the specific model.\u003c\/p\u003e\u003cp\u003eBrowse \u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eventilation and climate controllers\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115837112662,"sku":"12395","price":165.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/GSE-STEP-TRANSFORMER-controller-HUM-TEMP-1FAN-2-5A.webp?v=1792755533"},{"product_id":"g-se-ac-ec-fan-controller","title":"GSE AC-EC, intake and exhaust fan controller","description":"\u003cp\u003eThis LCD fan controller with built-in display and rotary knob makes it quick and easy to set and read all the information provided by the controller for the intake and exhaust fans. It displays the temperature, humidity and RPM speed of the EC exhaust fan. A built-in light sensor detects day\/night modes. Two 5A \/ 230V AC outputs for the intake and exhaust fans, plus two RJ45 EC outputs, with a choice of 0-10V or PWM (pulse-width modulation) signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSettings range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eTemperature: \u003cstrong\u003e15 - 35C°\u003c\/strong\u003e, Hysteresis \u003cstrong\u003e1 to 5C°\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eHumidity: \u003cstrong\u003e0 - 100%\u003c\/strong\u003e, Hysteresis \u003cstrong\u003e1 to 20%\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eMinimum speed: \u003cstrong\u003eoff\u003c\/strong\u003e, \u003cstrong\u003e1 to 100%\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eMaximum speed: \u003cstrong\u003e10 to 100%\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eNegative pressure: \u003cstrong\u003e0 to 50%\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTwo internal temperature sensors prevent the heatsink and processor components from overheating. However, if overheating occurs, variable control is switched off and a safety relay protects the exhaust fan while the intake fan is switched off. This way, the controller prevents complete ventilation failure and protects your plants.\u003c\/p\u003e\n\u003cp\u003eThe controller is ready to use. This reliable fan controller comes with a sealed, waterproof cover, covered sockets and a low-voltage sensor, making it ideal for humid environments. The sensor comes with a 4-meter cable. The controller is supplied with a 1.5-meter power cable and a 4-meter sensor cable, which can be extended to 10 meters if necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVideo instructions in English and Bulgarian: \u003ca href=\"https:\/\/www.youtube.com\/watch?v=SOHCaHWDh-I\u0026amp;ab_channel=AlainGressly\"\u003e\u003cu\u003ehere\u003c\/u\u003e\u003c\/a\u003e\u003c\/strong\u003e* and \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/ubm-bb69c4c2fadb478dd49f.pdf?v=1787840834\"\u003e\u003cu\u003e\u003cstrong\u003ehere\u003c\/strong\u003e\u003c\/u\u003e\u003c\/a\u003e*\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eTemperature during the day\u003c\/li\u003e\n\t\u003cli\u003eTemperature hysteresis during the day\u003c\/li\u003e\n\t\u003cli\u003eHumidity during the day\u003c\/li\u003e\n\t\u003cli\u003eHumidity hysteresis during the day\u003c\/li\u003e\n\t\u003cli\u003eMinimum speed during the day\u003c\/li\u003e\n\t\u003cli\u003eMaximum speed during the day\u003c\/li\u003e\n\t\u003cli\u003eTemperature at night\u003c\/li\u003e\n\t\u003cli\u003eTemperature hysteresis at night\u003c\/li\u003e\n\t\u003cli\u003eHumidity at night\u003c\/li\u003e\n\t\u003cli\u003eHumidity hysteresis at night\u003c\/li\u003e\n\t\u003cli\u003eMinimum speed at night\u003c\/li\u003e\n\t\u003cli\u003eMaximum speed at night\u003c\/li\u003e\n\t\u003cli\u003eNegative pressure setting\u003c\/li\u003e\n\t\u003cli\u003eSensor switching\u003c\/li\u003e\n\t\u003cli\u003eDay\/night mode switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLCD display:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eGraphical and digital display of constant speed in rpm\u003c\/li\u003e\n\t\u003cli\u003eConstant temperature display\u003c\/li\u003e\n\t\u003cli\u003eConstant humidity display\u003c\/li\u003e\n\t\u003cli\u003eOption to set the desired conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions and technical specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\t\u003cli\u003eHousing W x H x D: \u003cstrong\u003e130 x 92 x 105mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eController W x H x D: \u003cstrong\u003e160 x 130 x 105mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eDesigned for: \u003cstrong\u003e10A\u003c\/strong\u003e \/ \u003cstrong\u003e2 x 1150W\u003c\/strong\u003e \/ \u003cstrong\u003eTriac 2 x 16A\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eVoltage: \u003cstrong\u003e230V \/ 50HZ\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eDigital \u003cstrong\u003e5V\u003c\/strong\u003e sensor measures temperatures from\u003cstrong\u003e –55°C\u003c\/strong\u003e to \u003cstrong\u003e+125°C\u003c\/strong\u003e (–67°F to +257°F)\u003c\/li\u003e\n\t\u003cli\u003eTemperature accuracy from –10 to +85°C: \u003cstrong\u003e0.5°C \u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eHumidity accuracy \u003cstrong\u003e+\/-3%RH,\u003c\/strong\u003e max. tolerance\u003cstrong\u003e 55%RH\u003c\/strong\u003e\n\u003c\/li\u003e\n\t\u003cli\u003eProtection rating: \u003cstrong\u003eIP54\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eChoosing a climate controller\u003c\/h2\u003e\u003cp\u003eConsider the load type and control method. An AC fan with adjustable voltage and an EC fan with a control input require different control methods. Follow the limitations of the specific model.\u003c\/p\u003e\u003cp\u003eExplore \u003ca href=\"\/en\/collections\/timers-and-controllers-ventilation-and-climate\"\u003eventilation and climate controllers\u003c\/a\u003e.\u003c\/p\u003e","brand":"G-systems","offers":[{"title":"Default Title","offer_id":55115847434582,"sku":"12312","price":189.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/kontroler-za-vlazhnost-g-systems-2.webp?v=1792755786"},{"product_id":"gse-nexcontrol-32a-ac-ec","title":"GSE NexControl 32A AC\/EC – climate, CO₂, ventilation, and lighting controller","description":"\u003cp\u003e\u003cstrong\u003eGSE NexControl 32A AC\/EC\u003c\/strong\u003e is a professional controller for automated climate control in grow rooms. It combines control of \u003cstrong\u003eCO₂, temperature, humidity, ventilation, and lighting\u003c\/strong\u003e in one device, allowing precise maintenance of the set conditions throughout the day and night.\u003c\/p\u003e\n\u003cp\u003eThe controller can control AC fans via adjustable outputs, EC fans via a \u003cstrong\u003e0–10 V or PWM\u003c\/strong\u003e signal, and lighting via \u003cstrong\u003e0–10 V\u003c\/strong\u003e dimming. The four programmable outputs can be configured to respond to sensor readings or a timer to control heating, cooling, humidification, dehumidification, a CO₂ solenoid valve, and other connected devices.\u003c\/p\u003e\n\u003ch2\u003eMain features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCO₂ concentration control with a setpoint and hysteresis\u003c\/li\u003e\n\u003cli\u003eTemperature and humidity control with separate day and night settings\u003c\/li\u003e\n\u003cli\u003eControls intake and exhaust fans\u003c\/li\u003e\n\u003cli\u003eSupports AC and EC fans\u003c\/li\u003e\n\u003cli\u003eControl signals for EC fans: 0–10 V or PWM\u003c\/li\u003e\n\u003cli\u003eLighting control and dimming via 0–10 V\u003c\/li\u003e\n\u003cli\u003eProgrammable lighting schedule with sunrise and sunset simulation\u003c\/li\u003e\n\u003cli\u003e4 programmable outputs for climate control and auxiliary devices\u003c\/li\u003e\n\u003cli\u003eTemperature, humidity, and CO₂ alarms\u003c\/li\u003e\n\u003cli\u003eStores minimum and maximum measured values\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical specifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eGSE \/ G-Systems Engineering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003eNexControl 32A AC\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower supply\u003c\/th\u003e\n\u003ctd\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003ctd\u003eEU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput 1\u003c\/th\u003e\n\u003ctd\u003eAdjustable AC, min. 200 W \/ max. 10 A (2300 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput 2\u003c\/th\u003e\n\u003ctd\u003eAdjustable AC, min. 200 W \/ max. 10 A (2300 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput 3\u003c\/th\u003e\n\u003ctd\u003eRelay, max. 10 A (2300 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOutput 4\u003c\/th\u003e\n\u003ctd\u003eRelay, max. 10 A (2300 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower lines\u003c\/th\u003e\n\u003ctd\u003e2 × 16 A; the total load of each pair of outputs must not exceed 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEC fans\u003c\/th\u003e\n\u003ctd\u003e0–10 V or PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLighting\u003c\/th\u003e\n\u003ctd\u003e0–10 V control signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCO₂ range\u003c\/th\u003e\n\u003ctd\u003e400–5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCO₂ accuracy\u003c\/th\u003e\n\u003ctd\u003e±(40 ppm + 5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCombined sensor temperature range\u003c\/th\u003e\n\u003ctd\u003e−10°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTemperature accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHumidity accuracy\u003c\/th\u003e\n\u003ctd\u003e±5% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eExternal temperature sensor\u003c\/th\u003e\n\u003ctd\u003eDS18B20, −55°C to +125°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProtection rating\u003c\/th\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e3.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDimensions\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e 120 × 180 × 80 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController:\u003c\/strong\u003e 150 × 210 × 110 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSensors and control\u003c\/h2\u003e\n\u003cp\u003eThis configuration includes a sensor for \u003cstrong\u003eCO₂, temperature, humidity, and light\u003c\/strong\u003e. The controller monitors current readings and lets you set target parameters, alarms, and automatic responses from connected devices.\u003c\/p\u003e\n\u003ch2\u003eInstallation\u003c\/h2\u003e\n\u003cp\u003eThe device must be installed using the supplied mounting bracket on a solid, non-combustible surface and in a location with sufficient ventilation to dissipate heat. Installation in enclosed cabinets or spaces with limited air circulation is not recommended.\u003c\/p\u003e","brand":"UrbanBotaniks Grow Shop","offers":[{"title":"Default Title","offer_id":55954524143958,"sku":"12338","price":799.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/files\/image.png?v=1792660674"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1055\/7190\/9974\/collections\/original_image_469d9b7f4c80ec2af18074b46b982ce5.jpg?v=1793627935","url":"https:\/\/urbanbotaniks.com\/en\/collections\/timers-and-controllers-ventilation-and-climate-g-systems.oembed","provider":"UrbanBotaniks Grow Shop","version":"1.0","type":"link"}