Milwaukee MC122 PRO pH Controller

Automate controlling the pH of your solution using the Milwaukee MC122 PRO pH Controller!

The Milwaukee MC122 PRO pH Controller automatically monitors and fine-tunes pH levels. Simply set your pH parameters and let the MC122 PRO do the rest. Recommended for hydroponic plant growing or aquariums.

  • pH measurement accuracy: ± 0.2 with two-point manual calibration
  • control range: from 5.5 to 9.5 pH with alarms that are activated when readings are higher or lower than the set value
  • pH electrode: MA911B/2 (included )
  • compatible with Milwaukee MP810 metering pump 1.5l/h (25ml/min ) ( not included )
  • Device warranty: 2 years
  • pH probe warranty: 6 months

Quick Buy

Just 2 fields to fill in
We will contact you to finalize the order
Price: €184.68
Found a product at a lower price?
Add to wishlist

Estimated Shipping

to Plovdiv starts at €2.15outside Plovdiv starts at €2.25
to Sofia starts at €2.17outside Sofia starts at €2.17
Milwaukee MC122 PRO pH Controller
Milwaukee MC122 PRO pH Controller

Instructions for use here .

  • pH measurement accuracy: ± 0.2 with two-point manual calibration
  • control range: from 5.5 to 9.5 pH with alarms that are activated when readings are higher or lower than the set value
  • pH electrode: MA911B/2 (included )
  • compatible with Milwaukee MP810 metering pump 1.5l/h (25ml/min ) ( not included )
  • operating environment: 0 - 50°C ; max. 95% RH
  • power supply: 12 VDC adapter   ( included )
  • mounting kit: included
  • Dimensions: 15 x 8 x 3.4 cm
  • weight: 180 g

You can extend the life of your pH electrode in the following ways:

  1. Storage: The pH probe must be kept hydrated. Long periods of dry storage will impair the sensitivity of the probe. Allowing the probe to dry out can also lead to build-up and clogging of the tip. Storing in MA9015 Storage Solution or pH Calibration Buffers will help address both of these issues. Do not store in tap water or distilled water! This will impair the sensitivity of the probe. The best way to store the probe is with the probe cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that the electrode be stored upright to further reduce the potential for leakage.
  2. Cleaning: Build-up on the probe tip from mineral salts in the nutrient solution or organic material can affect sensitivity and clog it. We recommend regularly soaking your electrode in MA9016 cleaning solution .
  3. Calibration: The glass tip of the pH probe becomes less sensitive over time, so make sure to calibrate regularly to keep your Milwaukee MC122 PRO pH Controller accurate. Also, calibrate after cleaning or long periods of storage.