Welcome to UrbanBotaniks Grow Shop
Main menu
-
PromotionsSave
-
Seeds
-
Greenhouses
- Greenhouses
-
Garden solutions
Browse
-
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
-
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
-
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
-
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
-
Soils and pots
- Soils and pots
-
The right foundation
Browse -
Nutrition and care
Browse
-
Fertilizers and additives
-
Hydroponics and irrigation
-
Timers and controllers
-
Measuring instruments
-
Scissors and trimmers
-
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
-
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
-
Gifts
-
Brands
- Brands All brands
-
DUTCHPRO
-
FERRO
-
CELLMAX
-
T.A. - Terra Aquatica
-
Biobizz
-
CANNA
-
ATAMI
-
PLAGRON
-
GREEN HOUSE FEEDING
-
Xpert Nutrients
-
CANNA
Browse BioBizz
Browse
Your cart
Cornwall Temperature Controller, temperature thermostat
€45,00
Cornwall temperature controller, ideal for stabilizing the temperature of your crop. It can be used with an air conditioner or other heating appliances (heaters), depending on the selected function.
- Voltage: 230V AC/50HZ
- Maximum load: 16A 3680W
- Inductive load (exhaust fan): 2A 460W
- Operating temperature: 0°C - 40°C
- Storage temperature: -10°C - 50°C
- Controlled temperature: 5°C - 30°C / 40°F - 85°F
- Accuracy: ±1°C / ±3°F
- Reading interval: 10 sec
Please read the instructions before use:
- Before setting the temperature, select the operating mode - cooling (snowflake icon) or heating (flame icon). In "cooling" mode, the unit supplies power when the temperature exceeds the set value; in "heating" mode, it supplies power when the temperature drops below the set value. To change the operating mode - press ON/OFF and "up arrow" together for 3 seconds.
- To switch between °C and °F - press the "up arrow" and "down arrow" together for 3 seconds
- Default setting - cooling; 20°C
- Setting the temperature - press ON/OFF
Cooling mode:
- Use the arrows to set the "SET" temperature at least 2° below the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the snowflake icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is above the "RM" temperature, the indicator will glow red and the controller will not supply power.
Heating mode:
- Use the arrows to set the "SET" temperature at least 2° above the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the flame icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is below the "RM" temperature, the indicator will glow red and the controller will not supply power.
Important:
- Do not connect a power strip after the controller!
- Do not connect devices that transmit vibrations to the controller!
- Ensure the safety of heating and moving appliances!
- Protect from moisture, extreme temperatures, impacts, and vibrations!
- Use indoors only; do not expose to sunlight!
- Keep out of reach of children!
Charge the battery when the device displays "LO" - by plugging the device into the socket!
Distinguish between the maximum load of 16 A / 3680 W and the specified inductive load of 2 A / 460 W. For a motor, compressor, or other inductive appliance, observe the lower permissible limit.
Choosing a climate controller
Match the load type to the control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations for the specific model.
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
Cornwall Temperature Controller, temperature thermostat
€45,00
Share:
€45,00
€45,00
€45,00
Description
Cornwall temperature controller, ideal for stabilizing the temperature of your crop. It can be used with an air conditioner or other heating appliances (heaters), depending on the selected function.
- Voltage: 230V AC/50HZ
- Maximum load: 16A 3680W
- Inductive load (exhaust fan): 2A 460W
- Operating temperature: 0°C - 40°C
- Storage temperature: -10°C - 50°C
- Controlled temperature: 5°C - 30°C / 40°F - 85°F
- Accuracy: ±1°C / ±3°F
- Reading interval: 10 sec
Please read the instructions before use:
- Before setting the temperature, select the operating mode - cooling (snowflake icon) or heating (flame icon). In "cooling" mode, the unit supplies power when the temperature exceeds the set value; in "heating" mode, it supplies power when the temperature drops below the set value. To change the operating mode - press ON/OFF and "up arrow" together for 3 seconds.
- To switch between °C and °F - press the "up arrow" and "down arrow" together for 3 seconds
- Default setting - cooling; 20°C
- Setting the temperature - press ON/OFF
Cooling mode:
- Use the arrows to set the "SET" temperature at least 2° below the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the snowflake icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is above the "RM" temperature, the indicator will glow red and the controller will not supply power.
Heating mode:
- Use the arrows to set the "SET" temperature at least 2° above the "RM" temperature (the current measured temperature). After a few minutes, the indicator will glow green and the controller will start supplying power.
- When the "RM" temperature reaches the "SET" temperature, the indicator will glow red and the flame icon will disappear from the screen; the controller will stop supplying power.
- When the "SET" temperature is below the "RM" temperature, the indicator will glow red and the controller will not supply power.
Important:
- Do not connect a power strip after the controller!
- Do not connect devices that transmit vibrations to the controller!
- Ensure the safety of heating and moving appliances!
- Protect from moisture, extreme temperatures, impacts, and vibrations!
- Use indoors only; do not expose to sunlight!
- Keep out of reach of children!
Charge the battery when the device displays "LO" - by plugging the device into the socket!
Distinguish between the maximum load of 16 A / 3680 W and the specified inductive load of 2 A / 460 W. For a motor, compressor, or other inductive appliance, observe the lower permissible limit.
Choosing a climate controller
Match the load type to the control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations for the specific model.
More solutions for growing
€12,50
€8,50
€11,25
€0,18
€0,20
€7,50
€10,23
€12,00
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.