Welcome to UrbanBotaniks Grow Shop
Main menu
-
PromotionsSave
-
Seeds
-
Greenhouses
- Greenhouses
-
Garden solutions
Browse
-
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
-
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
-
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
-
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
-
Soils and pots
- Soils and pots
-
The right foundation
Browse -
Nutrition and care
Browse
-
Fertilizers and additives
-
Hydroponics and irrigation
-
Timers and controllers
-
Measuring instruments
-
Scissors and trimmers
-
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
-
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
-
Gifts
-
Brands
- Brands All brands
-
DUTCHPRO
-
FERRO
-
CELLMAX
-
T.A. - Terra Aquatica
-
Biobizz
-
CANNA
-
ATAMI
-
PLAGRON
-
GREEN HOUSE FEEDING
-
Xpert Nutrients
-
CANNA
Browse BioBizz
Browse
Your cart
GSE, temperature and minimum speed controller 5 A
€86,00
GSE temperature and minimum speed controller with 5A outlet is a speed controller for one or more exhaust fans used in indoor growing rooms.
- maintains a constant room temperature
- provides a continuous minimum speed to maintain basic air exchange
- max. current: 5.0A
- max. load: 1150W
Settings range:
- temperature: 20C° to 30C°
- min. speed: off, 20% to 100%
Technical specifications:
- dimensions W x H x D: 75x110x90mm.
- max. current: 5.0A
- max. load: 1150W
- temperature sensor with 2 m cable
- voltage: 230V, 50Hz
Installation:
- Plug the air fan into the outlet (5). Connect the temperature sensor (7), which has a 2 m cable, to the controller and choose a location for the sensor where you want to take the measurement.
- Make sure it is not directly exposed to a heat source or light, to ensure the most accurate measurement of the ambient air. Now plug the controller's plug (6) into an external outlet. The controller initializes, which can take up to 10 seconds; the green power LED (3) flashes, and the fans run at 50% power. After initialization, the green power LED (3) stays on continuously - the controller regulates from this point on.
Instructions:
- Use the temperature setting button (1) to set the desired temperature, for example, 24°C.
- Use the second knob to set the minimum speed (2), which should never drop during regulation; for example, we set it to 20%.
- The minimum speed setting is the most powerful setting and always overrides the temperature setting. If you set the minimum speed setting (2) to OFF, the fan will stop running when the measured temperature is below the set temperature. The minimum speed setting (2) has a 20% startup peak to provide enough power for the fan to run at low speed.
- The hysteresis is a fixed value of 2°C. Hysteresis is the controlled range of the fan speed. Within these 2°C, the fan speed will change from the lowest point, set by the minimum speed setting (2), to the highest control point, 100% fan speed, depending on the temperature.
- While the temperature measured by sensor (7) is below your setting (24°C), the minimum speed regulator keeps the fan running at the minimum speed setting (20%). As the temperature rises above 24°C, the temperature LED (4) turns on and the fan speed starts to increase based on the temperature over the next 2°C, up to 100% when it reaches 26°C.
- Small fans can be adjusted from 0-100%, but with higher power consumption (large fans), the controller operates in semi-variable mode and will automatically switch to 100%, without variable control. The controller stays on until the temperature drops.
- Warning! Setting a high minimum speed with large fans will cause them to run at 100% due to internal overheating protection! Lower the minimum speed!
Choosing a climate controller
Match the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations of the specific model.
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
GSE, temperature and minimum speed controller 5 A
€86,00
Share:
€86,00
€86,00
€86,00
Description
GSE temperature and minimum speed controller with 5A outlet is a speed controller for one or more exhaust fans used in indoor growing rooms.
- maintains a constant room temperature
- provides a continuous minimum speed to maintain basic air exchange
- max. current: 5.0A
- max. load: 1150W
Settings range:
- temperature: 20C° to 30C°
- min. speed: off, 20% to 100%
Technical specifications:
- dimensions W x H x D: 75x110x90mm.
- max. current: 5.0A
- max. load: 1150W
- temperature sensor with 2 m cable
- voltage: 230V, 50Hz
Installation:
- Plug the air fan into the outlet (5). Connect the temperature sensor (7), which has a 2 m cable, to the controller and choose a location for the sensor where you want to take the measurement.
- Make sure it is not directly exposed to a heat source or light, to ensure the most accurate measurement of the ambient air. Now plug the controller's plug (6) into an external outlet. The controller initializes, which can take up to 10 seconds; the green power LED (3) flashes, and the fans run at 50% power. After initialization, the green power LED (3) stays on continuously - the controller regulates from this point on.
Instructions:
- Use the temperature setting button (1) to set the desired temperature, for example, 24°C.
- Use the second knob to set the minimum speed (2), which should never drop during regulation; for example, we set it to 20%.
- The minimum speed setting is the most powerful setting and always overrides the temperature setting. If you set the minimum speed setting (2) to OFF, the fan will stop running when the measured temperature is below the set temperature. The minimum speed setting (2) has a 20% startup peak to provide enough power for the fan to run at low speed.
- The hysteresis is a fixed value of 2°C. Hysteresis is the controlled range of the fan speed. Within these 2°C, the fan speed will change from the lowest point, set by the minimum speed setting (2), to the highest control point, 100% fan speed, depending on the temperature.
- While the temperature measured by sensor (7) is below your setting (24°C), the minimum speed regulator keeps the fan running at the minimum speed setting (20%). As the temperature rises above 24°C, the temperature LED (4) turns on and the fan speed starts to increase based on the temperature over the next 2°C, up to 100% when it reaches 26°C.
- Small fans can be adjusted from 0-100%, but with higher power consumption (large fans), the controller operates in semi-variable mode and will automatically switch to 100%, without variable control. The controller stays on until the temperature drops.
- Warning! Setting a high minimum speed with large fans will cause them to run at 100% due to internal overheating protection! Lower the minimum speed!
Choosing a climate controller
Match the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different controls. Follow the limitations of the specific model.
More solutions for growing
€12,50
€8,50
€0,20
€12,00
€44,00
€12,50
€17,38
€3,20
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.