Welcome to UrbanBotaniks Grow Shop
Main menu
-
PromotionsSave
-
Seeds
-
Greenhouses
- Greenhouses
-
Garden solutions
Browse
-
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
-
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
-
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
-
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
-
Soils and pots
- Soils and pots
-
The right foundation
Browse -
Nutrition and care
Browse
-
Fertilizers and additives
-
Hydroponics and irrigation
-
Timers and controllers
-
Measuring instruments
-
Scissors and trimmers
-
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
-
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
-
Gifts
-
Brands
- Brands All brands
-
DUTCHPRO
-
FERRO
-
CELLMAX
-
T.A. - Terra Aquatica
-
Biobizz
-
CANNA
-
ATAMI
-
PLAGRON
-
GREEN HOUSE FEEDING
-
Xpert Nutrients
-
CANNA
Browse BioBizz
Browse
Your cart
GSE, dual-fan and negative-pressure controller
A controller with temperature, minimum speed, and negative pressure settings for controlling intake and exhaust fans.
Dimensions and technical data:
- Product dimensions: W80xH80xD130mm
- Package dimensions: W150xH110xD170mm
- Designed for: 2A / 2x200W / TRIAC 2x16A
- Voltage: 230V / 50HZ
- The 5V digital sensor measures temperatures from –55°C to +125°C (–67°F to +257°F )
- 0.5°C Accuracy from –10°C to +85°C
- Protection rating: IP54
Setting range:
- Temperature: from 20C° to 30C°
- Minimum speed: off, 20%, 100%
- Negative pressure: 100% to 50%
Instructions for use here!
- The controller operates one or two fans: one for intake and one for exhaust, or two for exhaust. Connect the exhaust fan to "Fan 1" and the intake fan to "Fan 2". Set the desired temperature.
- The "Minimum Speed" setting sets the exhaust fan's minimum speed as a percentage of its maximum speed. Set it to "Off" to stop ventilation when it isn't needed; any other setting will keep it running at the selected speed.
- The "Negative Pressure" setting sets the intake fan speed as a percentage of the exhaust fan speed. If you use this controller for 2 exhaust fans, set it to 100%; otherwise, determine a suitable value by experimentation.
- As the temperature rises, the fan speeds gradually increase, reaching 100% when the temperature rises by 2°. As the temperature drops, the speeds decrease again to the level set under "Minimum Speed".
- Maintains a constant temperature, while negative pressure contains odors.
- Can be used for two exhaust fans, provided there is free airflow into the room.
- Ready to use, reliable, with a waterproof housing, socket covers, and a low-voltage sensor, making it ideal for humid environments.
- The sensor has a 4m cable that can be extended up to 50m.
Negative pressure is adjusted by balancing the intake and exhaust fans. The TRIAC 2 × 16 A rating describes the components and does not mean a permitted load of 16 A on each fan output.
Choosing a climate controller
Match the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different control. Follow the limits for the specific model.
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
GSE, dual-fan and negative-pressure controller
Share:
Description
A controller with temperature, minimum speed, and negative pressure settings for controlling intake and exhaust fans.
Dimensions and technical data:
- Product dimensions: W80xH80xD130mm
- Package dimensions: W150xH110xD170mm
- Designed for: 2A / 2x200W / TRIAC 2x16A
- Voltage: 230V / 50HZ
- The 5V digital sensor measures temperatures from –55°C to +125°C (–67°F to +257°F )
- 0.5°C Accuracy from –10°C to +85°C
- Protection rating: IP54
Setting range:
- Temperature: from 20C° to 30C°
- Minimum speed: off, 20%, 100%
- Negative pressure: 100% to 50%
Instructions for use here!
- The controller operates one or two fans: one for intake and one for exhaust, or two for exhaust. Connect the exhaust fan to "Fan 1" and the intake fan to "Fan 2". Set the desired temperature.
- The "Minimum Speed" setting sets the exhaust fan's minimum speed as a percentage of its maximum speed. Set it to "Off" to stop ventilation when it isn't needed; any other setting will keep it running at the selected speed.
- The "Negative Pressure" setting sets the intake fan speed as a percentage of the exhaust fan speed. If you use this controller for 2 exhaust fans, set it to 100%; otherwise, determine a suitable value by experimentation.
- As the temperature rises, the fan speeds gradually increase, reaching 100% when the temperature rises by 2°. As the temperature drops, the speeds decrease again to the level set under "Minimum Speed".
- Maintains a constant temperature, while negative pressure contains odors.
- Can be used for two exhaust fans, provided there is free airflow into the room.
- Ready to use, reliable, with a waterproof housing, socket covers, and a low-voltage sensor, making it ideal for humid environments.
- The sensor has a 4m cable that can be extended up to 50m.
Negative pressure is adjusted by balancing the intake and exhaust fans. The TRIAC 2 × 16 A rating describes the components and does not mean a permitted load of 16 A on each fan output.
Choosing a climate controller
Match the load type and control method. An AC fan with adjustable voltage and an EC fan with a signal input require different control. Follow the limits for the specific model.
More solutions for growing
€12,50
€8,50
€0,20
€12,00
€44,00
€12,50
€17,38
€3,20
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.