Welcome to UrbanBotaniks Grow Shop
Main menu
PromotionsSave
Greenhouses
- Greenhouses
-
Garden solutions
Browse
Seeds
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
Soils and pots
Fertilizers and additives
Hydroponics and irrigation
Timers and controllers
Measuring instruments
Scissors and trimmers
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
Gifts
-
Brands
- Brands All brands
-
CANNA
Browse BioBizz
Browse
Your cart
Milwaukee MW802 PRO - Portable 3-in-1 Meter (pH, EC and TDS)
€288,00
This combined 3-in-1 meter lets you measure pH, EC (electrical conductivity) and TDS (total dissolved solids) with one meter and a single probe! Designed for growers
using hydroponics, aquaponics and greenhouses, Milwaukee MW802 PRO is exceptionally robust and easy to use – with one probe, a large screen and easy calibration. The meter’s robust construction and sturdy yet replaceable probe mean you can expect years of use. pH,
- EC (electrical conductivity), TDS (ppm) with automatic temperature compensation
- replaceable, integrated pH, EC and TDS (ppm) SE600 probe with a 1 m cable (included in
- the set) large, easy-to-read display
- factory calibrated (single-point calibration for pH and EC)
- measurement range: 0.00 - 14.00 pH / 0.00 - 6.00 mS/cm / 0 - 4000 ppm measurement accuracy: ±0.2 pH / ±2%
- full scale EC/TDS specially designed for use in
- hydroponics, aquariums and greenhouses Instructions for use and technical
specifications here. temperature compensation: automatic, 0 -
- 50°C calibration: initially factory, manual, single-point
- pH calibration: solution for pH
- 7.01 calibration - 20 ml EC / TDS calibration: 1413 µS/cm
- calibration solution - 20 ml or 1500 ppm calibration solution - 20 ml probe: integrated combination SE-600 operating environment: 0 - 50°C;
- max. 95% RH. battery
- type: 1 x 9V battery life: approximately 150
- hours of use automatic shut-off (auto-off)
- function: after 8 min. of inactivity dimensions:
- 143 x 80 x 32 mm weight: 220 g
- (with batteries) device warranty: 2 years
- probe warranty: 6 months pH
- and conductivity are extremely important
- for professional gardeners and large-scale
growers. pH can affect plants' uptake of nutrients and water and reduce the effectiveness of fertilisers, herbicides and pesticides. Managing conductivity helps growers determine the precise fertiliser or other plant needs. Care and use: The MW802 PRO portable 3-in-1 meter includes both a pH and
EC sensor in the integrated SE600 probe. All pH sensors have a limited lifespan, and their response time becomes longer over time. EC sensors are more robust but can still be affected by residue build-up. Both require maintenance. Proper maintenance of your probe will give you fast, accurate results for longer. Here are our four top tips. Always store with the cap filled with buffer
- or MA9015 storage solution, and not with water. Clean your probe regularly by soaking it in
- MA9016 cleaning solution. Calibrate after cleaning and/or storage before testing
- to correct changes in the pH and EC sensor. Gently stir the probe
- in the sample for a faster result.
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
Milwaukee MW802 PRO - Portable 3-in-1 Meter (pH, EC and TDS)
€288,00
Share:
€288,00
€288,00
€288,00
Description
This combined 3-in-1 meter lets you measure pH, EC (electrical conductivity) and TDS (total dissolved solids) with one meter and a single probe! Designed for growers
using hydroponics, aquaponics and greenhouses, Milwaukee MW802 PRO is exceptionally robust and easy to use – with one probe, a large screen and easy calibration. The meter’s robust construction and sturdy yet replaceable probe mean you can expect years of use. pH,
- EC (electrical conductivity), TDS (ppm) with automatic temperature compensation
- replaceable, integrated pH, EC and TDS (ppm) SE600 probe with a 1 m cable (included in
- the set) large, easy-to-read display
- factory calibrated (single-point calibration for pH and EC)
- measurement range: 0.00 - 14.00 pH / 0.00 - 6.00 mS/cm / 0 - 4000 ppm measurement accuracy: ±0.2 pH / ±2%
- full scale EC/TDS specially designed for use in
- hydroponics, aquariums and greenhouses Instructions for use and technical
specifications here. temperature compensation: automatic, 0 -
- 50°C calibration: initially factory, manual, single-point
- pH calibration: solution for pH
- 7.01 calibration - 20 ml EC / TDS calibration: 1413 µS/cm
- calibration solution - 20 ml or 1500 ppm calibration solution - 20 ml probe: integrated combination SE-600 operating environment: 0 - 50°C;
- max. 95% RH. battery
- type: 1 x 9V battery life: approximately 150
- hours of use automatic shut-off (auto-off)
- function: after 8 min. of inactivity dimensions:
- 143 x 80 x 32 mm weight: 220 g
- (with batteries) device warranty: 2 years
- probe warranty: 6 months pH
- and conductivity are extremely important
- for professional gardeners and large-scale
growers. pH can affect plants' uptake of nutrients and water and reduce the effectiveness of fertilisers, herbicides and pesticides. Managing conductivity helps growers determine the precise fertiliser or other plant needs. Care and use: The MW802 PRO portable 3-in-1 meter includes both a pH and
EC sensor in the integrated SE600 probe. All pH sensors have a limited lifespan, and their response time becomes longer over time. EC sensors are more robust but can still be affected by residue build-up. Both require maintenance. Proper maintenance of your probe will give you fast, accurate results for longer. Here are our four top tips. Always store with the cap filled with buffer
- or MA9015 storage solution, and not with water. Clean your probe regularly by soaking it in
- MA9016 cleaning solution. Calibrate after cleaning and/or storage before testing
- to correct changes in the pH and EC sensor. Gently stir the probe
- in the sample for a faster result.
More solutions for growing
€12,50
€8,50
€11,25
€0,18
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
When ordering products
over 50
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.