Welcome to UrbanBotaniks Grow Shop
Main menu
PromotionsSave
Greenhouses
- Greenhouses
-
Garden solutions
Browse
Seeds
Grow tents
- Grow tents
-
Controlled environment
Browse -
Fresh air
Browse
Lighting
- Lighting
-
Light for every stage
Browse -
Precision control
Browse
Ventilation and climate
- Ventilation and climate
-
Stable climate
Browse -
Measurement and control
Browse
Everything for seedlings
- Everything for seedlings
-
Strong start
Browse -
Growing systems
Browse
Soils and pots
Fertilizers and additives
Hydroponics and irrigation
Timers and controllers
Measuring instruments
Scissors and trimmers
Machines and equipment
- Machines and equipment
-
Equipment for professional work
Browse
Accessories and tools
- Accessories and tools
-
Practical helpers
Browse
Gifts
-
Brands
- Brands All brands
-
CANNA
Browse BioBizz
Browse
Your cart
TechGrow Clima Micro Plus, 2 × 2.5 A, Negative Pressure
€132,94
TechGrow - Clima Micro Plus 2 x 2.5A (Negative pressure) regulates the minimum speed of the exhaust fan until the desired temperature and desired negative air pressure are reached or maintained at the intake fan for optimal air circulation. The controller operates based on the minimum fan speed, temperature and hysteresis, negative air pressure and maximum fan speed (100%). The display shows the currently measured temperature and the recorded minimum / maximum values from the connected sensor.
- Controls the minimum speed of the exhaust fan until the desired temperature is reached or maintained
- Controls the negative air pressure of the intake fan for optimal air circulation
- Displays the current temperature and the recorded measured minimum/maximum values
- Minimum intake fan speed setting range: 10% - 100%
- Negative air pressure setting range of the intake fan: up to 50%
- Temperature setting range: 15° - 35°C
- Hysteresis setting range: 1°C - 5°C
- Minimum required sensor: TempProbe (not included)
Features:
- Controls the minimum speed of the exhaust fan until the desired temperature is reached or maintained
- Controls the negative air pressure of the intake fan for optimal air circulation
- Displays the current temperature and the recorded measured minimum/maximum values
- The set minimum fan speed, set temperature and set negative pressure are retained in the event of a power failure
- Minimum fan speed setting range: 10% - 100%
- Negative air pressure setting range of the intake fan: up to 50%
- Temperature setting range: 15° - 35°C
- Hysteresis setting range: 1°C - 5°C
- The display updates every second
- Automatic display backlight switch-off after 60 seconds
- Automatic detection of cable faults or poor sensor connection
- 2 UTP ports
- Easy fuse replacement (spare fuse included)
- Minimum required sensor: TempProbe (not included)
Technical specifications:
- Power supply: 100-240V
- Power consumption: 3W
- Fuse: 5A
- Power cable: 3x1.5 mm / 1.7 m
Compare products
|
__ __ |
|
|---|---|
| Brand |
Brand - __ |
| Availability |
Availability - __ |
| Options |
Options - __ |
| Description |
Description - __ |
| SKU |
SKU - __ |
|
|
Compare products ( / )
TechGrow Clima Micro Plus, 2 × 2.5 A, Negative Pressure
€132,94
This product is no longer available
This page remains available for product information and reference.
Share:
Description
TechGrow - Clima Micro Plus 2 x 2.5A (Negative pressure) regulates the minimum speed of the exhaust fan until the desired temperature and desired negative air pressure are reached or maintained at the intake fan for optimal air circulation. The controller operates based on the minimum fan speed, temperature and hysteresis, negative air pressure and maximum fan speed (100%). The display shows the currently measured temperature and the recorded minimum / maximum values from the connected sensor.
- Controls the minimum speed of the exhaust fan until the desired temperature is reached or maintained
- Controls the negative air pressure of the intake fan for optimal air circulation
- Displays the current temperature and the recorded measured minimum/maximum values
- Minimum intake fan speed setting range: 10% - 100%
- Negative air pressure setting range of the intake fan: up to 50%
- Temperature setting range: 15° - 35°C
- Hysteresis setting range: 1°C - 5°C
- Minimum required sensor: TempProbe (not included)
Features:
- Controls the minimum speed of the exhaust fan until the desired temperature is reached or maintained
- Controls the negative air pressure of the intake fan for optimal air circulation
- Displays the current temperature and the recorded measured minimum/maximum values
- The set minimum fan speed, set temperature and set negative pressure are retained in the event of a power failure
- Minimum fan speed setting range: 10% - 100%
- Negative air pressure setting range of the intake fan: up to 50%
- Temperature setting range: 15° - 35°C
- Hysteresis setting range: 1°C - 5°C
- The display updates every second
- Automatic display backlight switch-off after 60 seconds
- Automatic detection of cable faults or poor sensor connection
- 2 UTP ports
- Easy fuse replacement (spare fuse included)
- Minimum required sensor: TempProbe (not included)
Technical specifications:
- Power supply: 100-240V
- Power consumption: 3W
- Fuse: 5A
- Power cable: 3x1.5 mm / 1.7 m
More solutions for growing
€12,50
€8,50
€11,25
€0,18
Recently viewed
Useful categories
For all purchased
goods from our store
Ask about the option of
discreet delivery!
When ordering products
over 50
Contact our team for guidance and support.
- Choosing a selection results in a full page refresh.
- Opens in a new window.